    I wouldn't dry them in the drier at all unless there was a care tag that said the dryer was OK to use
  • S
    seasick replied to the thread fuel and spedo guage not workin.
    Ditto to what has been said, adding the question; " Do the gauges power up and go through the initial self test?" When you say that the...
  • S
    seasick replied to the thread Freedom Trim.
    And why is that a problem? What's more important to determine if the set up is working is knowing the WOT revs, adjusting engine trim...
  • S
    If mineral deposits are left on the glass for long periods and exposed to sunlight, the minerals will etch into the glass and bond to...
  • S
    seasick replied to the thread horn and radio.
    Horns go bad all the time, work on that last. Which radio, VHF? You need to take a look at the back of the radio and find the power and...
  • S
    seasick replied to the thread Sending Unit for Tournament 192.
    Unfortunately, I am having more of those lately.
  • S
    seasick replied to the thread Sending Unit for Tournament 192.
    At least I know that my posts are read. Did I say pickup??? Oops.
  • S
    There are four cushions for the 208 cabin: Port and starboard 'soft' cushions. Each side has different dimensions. The over the porta...
  • S
    seasick replied to the thread Transom Leaking.
    It may be a bit late. It is possible that the coring is soaked or that the glass has delaminated leaving a space for water to collect...
  • S
    seasick replied to the thread Starting.
    I concur, you probably left off a ground wire, perhaps the short one that ties the two negative terminals to each other.
  • S
    seasick replied to the thread Transom maintenance.
    You must have better luck than I do, I have often broken off SS screws on motor parts, like brackets, anodes, ground lugs etc.
  • S
    seasick replied to the thread Electrical problem of the day.
    Try a test lamp with an incandescent bulb and see if it lights when the test tip is touched to the 12 feed lead. Then move along to the...
  • S
    seasick replied to the thread Electrical problem of the day.
    The high voltage is measured wit the fixture n the ON state would indicate a bad ground.
  • S
    seasick replied to the thread Transom maintenance.
    If they used SS bolts and washers on aluminum plate without some sort of sealant as an insulator , there will be corrosion issues ...
  • S
    There may be a problem with the switch. It may have something internal that shorts the power to ground when in the off position. I...